evaluation by
professionals, but this is not required.
2. Standards of Practice
2.1. Roof
|
I.
The inspector shall inspect from ground level or eaves:
|
II.
The inspector is not required to:
|
|
A.
The roof covering.
B. The gutters.
C. The downspouts.
D. The vents, flashings, skylights, chimney and other roof penetrations.
E. The general structure of the roof from the readily accessible panels, doors or stairs.
|
A.
Walk on any roof surface.
B. Predict the service life expectancy.
C. Inspect underground downspout diverter drainage pipes.
D. Remove snow, ice, debris or other conditions that prohibit the
observation of the roof surfaces.
E. Inspect antennae, lightning arresters, or similar attachments.
|
2.2. Basement,
Foundation & Crawlspace
|
I.
The inspector shall inspect:
|
II.
The inspector is not required to:
|
|
A. The basement.
B. The foundation
C. The crawlspace.
D. The visible structural components.
E. Any present conditions or clear indications of active water
penetration observed by the inspector.
F. And report any general indications of foundation
movement that are observed by the inspector, such as but not limited to
sheetrock cracks, brick cracks, out-of-square door frames or floor slopes.
|
A. Enter any crawlspaces that are not readily
accessible or where entry could cause damage or pose a hazard to the
inspector.
B. Move stored items or debris.
C. Operate sump pumps with inaccessible floats.
D. Identify size, spacing, span, location or determine adequacy of
foundation bolting, bracing, joists, joist spans or support systems.
E. Provide any engineering or architectural service.
F. Report on the adequacy of any structural system or component.
|
2.3. Exterior
|
I.
The inspector shall inspect:
|
|
|
A. The siding, flashing and trim.
B. All exterior doors, decks, stoops, steps, stairs, porches, railings,
eaves, soffits and fascias.
C. And report as in need of repair any spacing between
intermediate balusters, spindles, or rails for steps, stairways, balconies,
and railings that permit the passage of an object greater than four inches
in diameter.
|
D. A
representative number of windows.
E. The vegetation, surface drainage and retaining walls when these are
likely to adversely affect the structure.
F. And describe the exterior wall covering.
|
|
II.
The inspector is not required to:
|
|
|
A. Inspect or operate screens, storm windows, shutters,
awnings, fences, outbuildings, or exterior accent lighting.
B. Inspect items, including window and door flashings, which are not
visible or readily accessible from the ground.
C. Inspect geological, geotechnical, hydrological and/or soil
conditions.
D. Inspect recreational facilities.
E. Inspect seawalls, break-walls and docks.
F. Inspect erosion control and earth stabilization measures.
G. Inspect for safety type glass.
H. Inspect underground utilities.
|
I.
Inspect underground items.
J. Inspect wells or springs.
K. Inspect solar systems.
L. Inspect swimming pools or spas.
M. Inspect septic systems or cesspools.
N. Inspect playground equipment.
O. Inspect sprinkler systems.
P. Inspect drain fields or drywells.
Q. Determine the integrity of the thermal window seals or damaged glass.
|
2.4. Heating
|
I. The inspector shall inspect:
|
|
|
A. The heating system and describe the energy source
and heating method using normal operating controls.
B. And report as in need of repair electric furnaces which do not operate.
|
C. And report if inspector deemed the furnace
inaccessible.
|
|
II. The inspector is not required to:
|
|
|
A. Inspect or evaluate interiors of flues or chimneys,
fire chambers, heat exchangers, humidifiers, dehumidifiers,
electronic air filters, solar heating systems, solar heating systems or
fuel tanks.
B. Inspect underground fuel tanks.
C. Determine the uniformity, temperature, flow, balance, distribution,
size, capacity, BTU, or supply adequacy of the heating system.
|
D. Light or ignite pilot flames.
E. Activate heating, heat pump systems, or other heating systems when
ambient temperatures or when other circumstances are not conducive to safe
operation or may damage the equipment.
F. Override electronic thermostats.
G. Evaluate fuel quality.
H. Verify thermostat calibration, heat
anticipation or automatic setbacks, timers, programs or clocks.
|
2.5. Cooling
|
I. The inspector shall inspect:
|
|
|
A. The central cooling equipment using normal operating
controls.
|
|
|
II. The inspector is not required to:
|
|
|
A. Determine the uniformity, temperature, flow,
balance, distribution, size, capacity, BTU, or supply adequacy of the cooling
system.
B. Inspect window units, through-wall units, or electronic air filters.
C. Examine electrical current, coolant fluids or gasses, or coolant
leakage.
|
D. Operate equipment or systems if exterior temperature
is below 60 degrees Fahrenheit or when other circumstances are not
conducive to safe operation or may damage the equipment.
E. Inspect or determine thermostat calibration, heat anticipation or
automatic setbacks or clocks.
|
2.6.
Attic, Ventilation & Insulation
|
I. The inspector shall inspect:
|
|
|
A. The insulation in unfinished spaces.
B. The ventilation of attic spaces.
|
C. Mechanical ventilation systems.
D. And report on the general absence or lack of insulation.
|
|
II. The inspector is not required to:
|
|
|
A. Enter the attic or unfinished spaces that are not
readily accessible or where entry could cause damage or pose a safety
hazard to the inspector in his or her opinion.
B. To move, touch, or disturb insulation.
C. To move, touch or disturb vapor retarders.
D. Break or otherwise damage the surface finish or weather seal on or
around access panels and covers.
|
E. Identify the composition of or the exact R-value of
insulation material.
F. Activate thermostatically operated fans.
G. Determine the types of materials used in insulation/wrapping of pipes,
ducts, jackets, boilers, and wiring.
H. Determine adequacy of ventilation.
|
2.7. Plumbing
|
I.
The inspector shall:
|
II.
The inspector is not required to:
|
|
A. Verify the presence of and identify the location of
the main water shutoff valve.
B. Inspect the water heating equipment, including combustion air,
venting, connections, energy sources, seismic bracing, and verify the
presence or absence of temperature-pressure relief valves and/or Watts 210 valves.
C. Flush toilets.
D. Run water in sinks, tubs, and showers.
E. Inspect the interior water supply including all fixtures and faucets.
F. Inspect the drain, waste and vent systems, including all fixtures.
G. Describe any visible fuel storage systems.
H. Inspect the drainage sump pumps testing sumps with accessible floats.
I. Inspect and describe the water supply, drain, waste and main fuel
shut-off valves, as well as the location of the water main and main fuel
shut-off valves.
J. Inspect and determine if the water supply is public or private.
K. Inspect and report as in need of repair deficiencies in the water supply
by viewing the functional flow in two fixtures operated simultaneously.
L. Inspect and report as in need of repair deficiencies in installation and
identification of hot and cold faucets.
M. Inspect and report as in need of repair mechanical drain-stops that are
missing or do not operate if installed in sinks, lavatories and tubs.
N. Inspect and report as in need of repair commodes that have cracks in the
ceramic material, are improperly mounted on the floor, leak, or have tank
components which do not operate.
|
A. Light or ignite pilot flames.
B. Determine the size, temperature, age, life expectancy or adequacy of the
water heater.
C. Inspect interiors of flues or chimneys, water softening or filtering
systems, well pumps or tanks, safety or shut-of valves, floor drains, lawn
sprinkler systems or fire sprinkler systems.
D. Determine the exact flow rate, volume, pressure, temperature, or
adequacy of the water supply.
E. Determine the water quality or portability or the reliability of the
water supply or source.
F. Open sealed plumbing access panels.
G. Inspect clothes washing machines or their connections.
H. Operate any main, branch or fixture valve.
I. Test shower pans, tub and shower surrounds or
enclosures for leakage.
J. Evaluate the compliance with local or state conservation or energy
standards, or the proper design or sizing of any water, waste or venting
components, fixtures or piping.
K. Determine the effectiveness of anti-siphon, back-flow prevention or
drain-stop devices.
L. Determine whether there are sufficient clean-outs for effective cleaning
of drains.
M. Evaluate gas, liquid propane or oil storage tanks.
N. Inspect any private sewage waste disposal system or component of.
O. Inspect water treatment systems or water filters.
P. Inspect water storage tanks, pressure pumps or bladder tanks.
Q. Evaluate time to obtain hot water at fixtures, or
perform testing of any kind to water heater elements.
R. Evaluate or determine the adequacy of combustion
air.
S. Test, operate, open or close safety controls, manual
stop valves and/or temperature or pressure relief valves.
T. Examine ancillary systems or components, such as,
but not limited to, those relating to solar water heating, hot water
circulation.
|
2.8. Electrical
|
I.
The inspector shall inspect:
|
II.
The inspector is not required to:
|
|
A. The service line.
B. The meter box.
C. The main disconnect.
D. And determine the rating of the service amperage.
E. Panels, breakers and fuses.
F. The service grounding and bonding.
H. A representative sampling of switches, receptacles, light fixtures, AFCI
receptacles
I. And test all GFCI receptacles and GFCI circuit
breakers observed and deemed to be GFCIs during the inspection.
I. And report the presence of solid conductor aluminum
branch circuit wiring if readily visible.
J. And report on any GFCI-tested receptacles in which power is
not present, polarity is incorrect, the receptacle is not
grounded, is not secured to the wall, the cover is not in place, the
ground fault circuit interrupter devices are not properly installed or do
not operate properly, or evidence of arcing or excessive heat is
present.
K. The service entrance conductors and the condition of their
sheathing.
L. The ground fault circuit interrupters observed and deemed to be GFCIs
during the inspection with a GFCI tester.
M. And describe the amperage rating of the service.
N. And report the absence of smoke detectors.
O. Service entrance cables and report as in need of repair deficiencies in
the integrity of the insulation, drip loop, or separation of conductors at
weather heads and clearances.
|
A.
Insert any tool, probe or device into the main panel, sub-panels,
downstream panels, or electrical fixtures.
B. Operate electrical systems that are shut down.
C. Remove panel covers or dead front covers if not readily accessible.
D. Operate over current protection devices.
E. Operate non-accessible smoke detectors.
F. Measure or determine the amperage or voltage of the main service if not
visibly labeled.
G. Inspect the alarm system and components.
H. Inspect the ancillary wiring or remote control devices.
I. Activate any electrical systems or branch circuits which are not
energized.
J. Operate overload devices.
K. Inspect low voltage systems, electrical de-icing tapes, swimming pool
wiring or any time-controlled devices.
L. Verify the continuity of the connected service ground.
M. Inspect private or emergency electrical supply sources, including but
not limited to generators, windmills, photovoltaic solar collectors, or
battery or electrical storage facility.
N. Inspect spark or lightning arrestors.
O. Conduct voltage drop calculations.
P. Determine the accuracy of breaker labeling.
|
2.9. Fireplace
|
I.
The inspector shall inspect:
|
|
|
A.
The fireplace, and open and close the damper door if readily accessible and
operable.
B. Hearth extensions and other permanently installed components.
|
C. And report as in need of repair deficiencies in the
lintel, hearth and material surrounding the fireplace, including clearance
from combustible materials
|
|
II.
The inspector is not required to:
|
|
|
A.
Inspect the flue or vent system.
B. Inspect the interior of chimneys or flues, fire doors or screens,
seals or gaskets, or mantels.
C. Determine the need for a chimney sweep.
D. Operate gas fireplace inserts.
E. Light pilot flames.
F. Determine the appropriateness of such installation.
G. Inspect automatic fuel feed devices.
H. Inspect combustion and/or make-up air devices.
|
I. Inspect heat distribution assists whether gravity
controlled or fan assisted.
J. Ignite or extinguish fires.
K. Determine draft characteristics.
L. Move fireplace inserts, stoves, or firebox contents.
M. Determine adequacy of draft, perform a smoke test or dismantle or remove
any component.
N. Perform an NFPA inspection.
|
2.10. Doors,
Windows & Interior
|
I. The inspector shall:
|
|
|
A. Inspect the walls, ceilings, steps, stairways, and
railings.
B. Inspect garage doors and garage door openers by operating first
by remote (if available) and then by the installed automatic door
control.
C. And report as in need of repair any windows that are obviously fogged or
display other evidence of broken seals.
|
D. And report as in need of repair any installed
electronic sensors that are not operable or not installed at proper heights
above the garage door.
E. And report as in need of repair any door locks or side ropes that have
not been removed or disabled when garage door opener is in use.
F. Open and close a representative number of doors and
windows.
|
|
II. The inspector is not required to:
|
|
|
A. Inspect paint, wallpaper, window
treatments or finish treatments.
B. Inspect central vacuum systems.
C. Inspect safety glazing.
D. Inspect security systems or components.
E. Evaluate the fastening of countertops, cabinets, sink tops and fixtures,
or firewall compromises.
F. Move furniture, stored items, or any coverings like carpets or rugs in
order to inspect the concealed floor structure.
G. Move drop ceiling tiles.
H. Inspect or move any household appliances..
I. Inspect or operate equipment housed in the garage except as otherwise
noted.
J. Verify or certify safe operation of any auto reverse or related safety
function of a garage door.
K. Operate or evaluate security bar release and opening mechanisms, whether
interior or exterior, including compliance with local, state, or federal
standards.
L. Operate any system, appliance or component that requires the use of
special keys, codes, combinations, or devices.
M. Operate or evaluate self-cleaning oven cycles, tilt
guards/latches or signal lights.
|
N. Inspect microwave ovens or test leakage from
microwave ovens.
O. Operate or examine any sauna, steam-jenny, kiln, toaster, ice-maker,
coffee-maker, can-opener, bread-warmer, blender, instant hot water
dispenser, or other small, ancillary devices.
P. Inspect elevators.
Q. Inspect remote controls.
R. Inspect appliances.
S. Inspect items not permanently installed.
T. Examine or operate any above-ground, movable, freestanding, or otherwise
non-permanently installed pool/spa, recreational equipment or
self-contained equipment.
U. Come into contact with any pool or spa water in order to determine the
system structure or components.
V. Determine the adequacy of spa jet water force or bubble effect.
W. Determine the structural integrity or leakage of a pool or spa.
|
3. Limitations, Exceptions
& Exclusions
|
3.1.
Limitations:
|
|
|
I.
An inspection is not technically exhaustive.
II. An inspection will not identify concealed or latent defects.
III. An inspection will not deal with aesthetic concerns or what could be
deemed matters of taste, cosmetic, etc.
IV. An inspection will not determine the suitability of the property for
any use.
V. An inspection does not determine the market value of the property or its
marketability.
|
VI.
An inspection does not determine the advisability or inadvisability of the
purchase of the inspected property.
VII. An inspection does not determine the life expectancy of the property
or any components or systems therein.
VIII. An inspection does not include items not permanently installed.
IX. These Standards of Practice apply only to homes with four or fewer
dwelling units.
|
3.2. Exclusions:
|
I.
The inspectors are not required to determine:
|
II.
The inspectors are not required to operate:
|
|
A.
Property boundary lines or encroachments.
B. The condition of any component or system that is not readily accessible.
C. The service life expectancy of any component or system.
D. The size, capacity, BTU, performance, or efficiency of any component or
system.
E. The cause or reason of any condition.
F. The cause for the need of repair or replacement of any system or
component.
G. Future conditions.
H. The compliance with codes or regulations.
I. The presence of evidence of rodents, animals or insects.
J. The presence of mold, mildew or fungus.
K. The presence of air-borne hazards.
L. The presence of birds.
M. The presence of other flora or fauna.
N. The air quality.
O. The existence of asbestos.
P. The existence of environmental hazards.
Q. The existence of electro-magnetic fields.
R. The presence of hazardous materials including, but not limited to, the
presence of lead in paint.
S. Any hazardous waste conditions.
T. Any manufacturer recalls or conformance with manufacturer installation
or any information included in the consumer protection bulletin.
U. Operating costs of systems.
V. Replacement or repair cost estimates.
W. The acoustical properties of any systems.
X. Estimates of how much it will cost to run any given system.
|
A.
Any system that is shut down.
B. Any system that does not function properly.
C. Or evaluate low voltage electrical systems such as, but not limited to:
1. Phone lines.
2. Cable lines.
3. Antennae.
4. Lights.
5. Remote controls.
D. Any system that does not turn on with the use of normal operating
controls.
E. Any shut off valves or manual stop valves.
F. Any electrical disconnect or over current protection devices.
G. Any alarm systems.
H. Moisture meters, gas detectors or similar equipment.
|
3.2. Exclusions:
|
III.
The inspectors are not required to:
|
|
|
A.
Move any personal items or other obstructions, such as, but not limited to:
|
1.
Throw rugs.
2. Furniture.
3. Floor or wall coverings.
4. Ceiling tiles
5. Window coverings.
6. Equipment.
7. Plants.
|
8.
Ice.
9. Debris.
10. Snow.
11. Water.
12. Dirt.
13. Foliage.
14. Pets
|
B. Dismantle, open, or uncover any system or component.
C. Enter or access any area which may, in the opinion of the inspector, to
be unsafe or risk personal safety.
D. Enter crawlspaces or other areas that are unsafe or not readily
accessible.
E. Inspect underground items such as, but not limited to, underground
storage tanks or other indications of their presence, whether abandoned or
actively used.
F. Do anything which, in the inspector's opinion, is likely to be unsafe or
dangerous to the inspector or others or damage property, such as, but not
limited to, walking on roof surfaces, climbing ladders, entering attic
spaces or negotiating with dogs
|
G. Inspect decorative items.
H. Inspect common elements or areas in multi-unit housing.
I. Inspect intercoms, speaker systems, radio-controlled, security devices
or lawn irrigation systems.
J. Offer guarantees or warranties.
K. Offer or perform any engineering services.
L. Offer or perform any trade or professional service other than home
inspection.
M. Research the history of the property, report on its potential for
alteration, modification, extendibility, or its suitability for a specific
or proposed use for occupancy.
N. Determine the age of construction or installation of any system
structure, or component of a building, or differentiate between original
construction or subsequent additions, improvements, renovations or
replacements thereto.
O. Determine the insurability of a property.
P. Perform or offer Phase 1 environmental audits.
Q. Inspect on any system or component which is not
included in these standards.
|
4. Glossary of Terms
|
4.1. Accessible: Can be approached or entered by the
inspector safely, without difficulty, fear or danger.
4.2. Activate: To turn on, supply power, or enable
systems, equipment, or devices to become active by normal operating
controls. Examples include turning on the gas or water supply valves to the
fixtures and appliances and activating electrical breakers or fuses.
4.3. Adversely Affect: Constitute, or potentially
constitute, a negative or destructive impact.
4.4. Alarm System: Warning devices, installed or free-standing,
including but not limited to: Carbon monoxide detectors, flue gas and other
spillage detectors, security equipment, ejector pumps and smoke alarms.
4.5. Appliance: A household device operated by use of
electricity or gas. Not included in this definition are components covered
under central heating, central cooling or plumbing.
4.6. Architectural Service: Any practice involving the
art and science of building design for construction of any structure or
grouping of structures and the use of space within and surrounding the
structures or the design, design development, preparation of construction
contract documents, and administration of the construction contract.
4.7. Component: A permanently installed or attached
fixture, element or part of a system.
4.8. Condition: The visible and conspicuous state of
being of an object.
4.9. Crawlspace: The area within the confines of the
foundation and between the ground and the underside of the lowest floor
structural component.
4.10. Decorative: Ornamental; not required for the
operation of essential systems and components of a home.
4.11. Describe: Report in writing a system or component
by its type, or other observed characteristics, to distinguish it from
other components used for the same purpose.
4.12. Determine: To arrive at an opinion or conclusion
pursuant to examination.
4.13. Dismantle: To open, take apart or remove any
component, device or piece that would not typically be opened, taken apart
or removed by an ordinary occupant.
4.14. Engineering Service: Any professional service or
creative work requiring engineering education, training, and experience and
the application of special knowledge of the mathematical, physical and
engineering sciences to such professional service or creative work as consultation,
investigation, evaluation, planning, design and supervision of construction
for the purpose of assuring compliance with the specifications and design,
in conjunction with structures, buildings, machines, equipment, works or
processes.
4.15. Enter: To go into an area to observe visible
components.
4.16. Evaluate: To assess the systems, structures or
components of a dwelling.
4.17. Examine: To visually look. See Inspect.
4.18. Foundation: The base upon which the structure or
wall rests; usually masonry, concrete, or stone, and generally partially underground.
4.19. Function: The action for which an item,
component, or system is specially fitted or used or for which an item,
component or system exists; to be in action or perform a task.
4.20. Functional: Performing, or able to perform, a
function.
4.21. Home Inspection: The process by which an
inspector visually examines the readily accessible systems and components
of a home and operates those systems and components utilizing these
Standards of Practice as a guideline.
4.22. Household Appliances: Kitchen and laundry
appliances, room air conditioners, and similar appliances.
|
4.23. Inspect: To visually look at readily accessible
systems and components safely, using normal operating controls and accessing
readily accessible panels and areas in accordance with these Standards of
Practice.
4.24. Inspected Property: The readily accessible areas of the buildings,
site, items, components, and systems included in the inspection.
4.25. Inspector: One who performs a real estate inspection.
4.26. Installed: Attached or connected such that the
installed item requires tool for removal.
4.27. Material Defect: Refer to section 1.2.
4.28. Normal Operating Controls: Devices such as
thermostats that would be operated by ordinary occupants which require no
specialized skill or knowledge.
4.29. Observe: To see through visually directed
attention.
4.30. Operate: To cause systems to function or turn on
with normal operating controls.
4.31. Readily Accessible: An item or component is
readily accessible if, in the judgment of the inspector, it is capable of
being safely observed without movement of obstacles, detachment or
disengagement of connecting or securing devices, or other unsafe or
difficult procedures to gain access.
4.32. Recreational Facilities: Spas, saunas, steam baths,
swimming pools, tennis courts, playground equipment, and other exercise,
entertainment or athletic facilities.
4.33. Report: A written communication (possibly
including digital images) of any material defects seen during the
inspection.
4.34. Representative Number: A sufficient number to
serve as a typical or characteristic example of the item(s) inspected.
4.35. Safety Glazing: Tempered glass, laminated glass,
or rigid plastic.
4.36. Shut Down: Turned off, unplugged, inactive, not
in service, not operational, etc.
4.37. Structural Component: A component which supports
non-variable forces or weights (dead loads) and variable forces or weights
(live loads).
4.38. System: An assembly of various components to
function as a whole.
4.39. Technically Exhaustive: A comprehensive and
detailed examination beyond the scope of a real estate home inspection
which would involve or include, but would not be limited to: dismantling,
specialized knowledge or training, special equipment, measurements, calculations,
testing, research, analysis or other means.
4.40. Unsafe: A condition in a readily accessible,
installed system or component which is judged to be a significant risk of
personal injury during normal, day-to-day use. The risk may be due to
damage, deterioration, improper installation or a change in accepted
residential construction standards.
4.41. Verify: To confirm or substantiate.
|
|